Typical Project Configuration · Customizable Range · 800kW

800 kW Cummins + Leroy-Somer Open Diesel Generator

For large factories, critical facilities and higher-capacity backup projects. The brand combination is only the starting point; load steps, temperature rise, cooling, protection and local service must be verified together.

800 kWCummins engineLeroy-Somer alternatorLarge-load backup

Product photos · Typical configuration

Configuration overview

Reference 800 kW open generator with Cummins engine and Leroy-Somer alternator, covering large-load applications, transient performance, key parameters and acceptance.

Reference output
800 kW / 1000 kVA @ PF 0.8
Package format
Open package for a compliant generator room
Engine platform
Cummins
Alternator
Leroy-Somer / Nidec Power
Frequency and speed
50Hz / 1500rpm · 60Hz / 1800rpm
Electrical output
Three-phase, four-wire · Project voltage

This page presents one typical project configuration to explain output, brand combination, package format and system interfaces. The same range covers additional outputs and options; the final engine model, rating, voltage, controller, tank, dimensions and supply scope are defined for the project.

Applications

Recommended applications and package choice

Recommended for

For generator-room projects with large loads and established brand requirements

Suitable for major production facilities, data and communications auxiliaries, hospital back-of-house loads and multi-feeder critical systems with ATS, distribution or paralleling.

Consider another package

Do not compare the engine brand while ignoring the complete generator set

Alternator excitation, control protection, cooling, breaker selection and complete-set FAT all affect loaded performance and must be checked against the BOM.

Typical application
Large factories and critical facilities
Typical application
Hospital, data and communications auxiliaries
Typical application
Prime unit within ATS or paralleling systems

Core configuration

Four core configurations behind reliable operation

01

Engine and cooling

The engine and radiator are matched to output, duty and ambient temperature, with attention to load response, service access and local support.

02

Alternator

The alternator is selected for load characteristics, excitation, insulation and temperature rise; PMG can be specified for demanding motors or UPS loads.

03

Controls and protection

The controller can integrate ATS, paralleling and remote communications together with breaker, emergency stop, charging and protection functions.

04

Structure and interfaces

The base, mounts, grounding, cable exit and lifting interfaces form the package structure; container versions also integrate airflow, exhaust, weatherproof doors and service space.

Key parameters

Parameters used for project selection

These are the parameters that shape selection and interfaces. Fuel consumption, noise and dimensions are supplied after the engine model, load factor and site environment are defined.

Reference output800 kW / 1000 kVA @ PF 0.8
Rating basisPrime/standby rating confirmed against the final engine model, ISO 8528 conditions and project duty
Frequency / speed50 Hz / 1500 rpm or 60 Hz / 1800 rpm
Rated voltage380 / 400 / 415 / 440 / 480 V; other voltages by project
Phase / power factorThree-phase, four-wire; reference PF 0.8
Control systemDSE / ComAp / SmartGen selected for ATS, paralleling and communications
Cooling and environmentMatched radiator; 40°C or 50°C ambient capability verified by model
Fuel autonomyBase tank, day tank or bulk storage sized from target runtime and usable fuel volume

Quality and delivery

Delivery evidence from components and structure to testing

01

Nameplates and BOM

Engine, alternator, controller and breaker brands, models and serial information are listed in the technical and delivery documents.

02

Structure and workmanship

Base steel, welds, fasteners, mounts and coating are included in manufacturing inspection; container packages also cover doors, hinges, locks, seals and lifting points.

03

Cooling and electrical

Radiator, airflow, wiring terminations, grounding, protection and safety separation support loaded stability and long-term serviceability.

04

Factory-test records

Factory records can cover starting, no-load and staged-load operation, voltage, frequency, alarms and protection, with witnessed FAT available by project.

Project configuration

Optional systems and project inputs

Optional systems

  • ATS transfer and low-voltage distribution
  • Paralleling, N+1 and future expansion
  • Base tank, day tank and automatic transfer
  • Remote monitoring, communications and records
  • Breaker, charger, heaters and spares package
  • Special voltage, hot/high-altitude and corrosion protection

Information needed for an accurate proposal

  • Critical-load list, maximum simultaneous load and starting sequence
  • Prime/standby duty and expected annual operating hours
  • Country, frequency, voltage, grounding and grid boundary
  • Temperature, altitude, dust, salt exposure and noise target
  • Fuel runtime, refueling route and fire requirements
  • Transport, lifting, foundation, installation and FAT/SAT responsibility

Ask an engineer to verify this package against the real loads

Provide the country and city, load list, frequency, voltage, duty, installation environment and required delivery. A HOHANK engineer will verify output, component selection, interfaces and the supply boundary.

Get Engineering Support